eCat A/K-Series

eCat A14

High Agility,  Platform Scalable,  Flexible Payload

Twin-screw electric cat where maximum payload capability and operation in open water is required.

Hull Type

Catamaran hulls constructed from rotomolded polyethylene for maximum durability and impact resistance.
Designed specifically for efficient operation at survey speeds (~1.5 to 2.5  m/s) with burst speeds upwards of 9 m/s.

Sensor Payload

Capable of carrying larger and heavier  payloads than a Standard Jetyak

Special-missions payloads to specific requirements can be integrated by the client or ICS

Specifications

Physical

Motors: BLDC inrunner
Propulsion: Dual  Prop Thrusters
Hull Construction: Rotomolded PE (A-Series); FRK (K-Series)
Overall Dimensions:
      Length: 14ft (A14); 15-18 ft (K15-K18)
      Beam: 80" (A14); 96" (K15-K18)
Draft (without sensors): 8" /  200 mm (with motors up); 14" / 360mm (motors down) (A14)
Mass (approx.):  380 lb  / 170 kg (A14 w/ single battery)

Electrical

Motor Power: 5.5 kW (typ) BLDC inrunner @ 54 VDC
Battery System: 1 or 2 (optional) x 48V 96AH 4.6 kWh Deep Cycle LiFePO4; Integral BMS including cell balancing, low & high voltage cutoff, short circuit and temperature protection beyond operating range of -20° to +120°F; 100A max. cont. discharge current (200A for 3-5 minutes); 35kg mass (each)
Cabling: Sealed cables, connectors and penetrators for all power, control and data lines

Cooling

Active single-circuit heat exchanger for motors and ESCs w/ heat rejection via open-loop seawater circuits

Capability (A14)

Mission Payload Capacity:  500 lbs / 225 kg
Shallowest Launch Depth:  8" /  200 mm
Typical Endurance1: 7 hr @ 2 m/s with no sensors
Max Survey Speed: Sensor Dependent
Max Speed:  18 kt / 9 m/s
Max Wind: 20 kt / 10 m/s  depending on sea state
Max Wave2::  1.5 foot (0.50 m) typ. (sea state 3)
1Endurance for A14 taken at @ 2 m/s survey speed, 96Ah (4.6 Wh) total battery capacity under actual field operating conditions in low currents.
2Max Wave Height depends on wave period and amount of breaking

Measured Accuracy

Sensor Dependent. Consult Factory